GDS-1000B Programming Manual
98
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the RMS value.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:RMS?
1.31E-3
Selects Channel 1, and then measures the RMS
voltage/current.
:MEASure:CRMS
Description
Returns the root-mean-square voltage/current of
one full period.
Syntax
:MEASure:CRMS{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the CRMS value.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:CRMS?
1.31E-3
Selects Channel 1, and then measures the CRMS
voltage/current.
Query