EasyManua.ls Logo

GW Instek GDS-1000B Series - Search:trigger:bus:b1:Can:condition; Search:trigger:bus:b1:Spi:data:mosi:value

GW Instek GDS-1000B Series
259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GDS-1000B Programming Manual
208
Example 2
:SEARCH:TRIGger:BUS:B1:SPI:DATa:MISO:VALue?
1X1X0101
:SEARCH:TRIGger:BUS:B1:SPI:DATa:MOSI:
VALue
Description
Sets or queries the search triggering data value for
the SPI bus when the bus is set to trigger on MOSI
or MISO/MOSI.
Syntax
:SEARCH:TRIGger:BUS:B1:SPI:DATa:MOSI:VALue
{<string> | ? }
Related
commands
:SEARCH:TRIGger:BUS:B1:SPI:DATa:SIZe
Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double
quotes, "string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example1
:SEARCH:TRIGger:BUS:B1:SPI:CONDition MOSI
:SEARCH:TRIGger:BUS:B1:SPI:DATa:SIZe 2
:SEARCH:TRIGger:BUS:B1:SPI:DATa:MOSI:VALue
"1x1x0101"
Sets the value to 1x1x0101
Example2
:SEARCH:TRIGger:BUS:B1:SPI:DATa:MOSI:VALue?
1X1X0101
:SEARCH:TRIGger:BUS:B1:CAN:CONDition
Description
Sets or returns the CAN search trigger condition.
Set
Query
Set
Query

Table of Contents

Other manuals for GW Instek GDS-1000B Series

Related product manuals