COMMAND DETAILS
193
:SEARCH:TRIGger:RUNT:POLarity
Description
Sets or queries the Pulse Runt search trigger
polarity.
Syntax
:SEARCH:TRIGger:RUNT:POLarity {POSitive |
NEGative | EITher | ?}
Related
commands
:SEARCH:TRIGger:TYPe
Parameter
POSitive
Positive polarity
NEGative
Negative polarity
EITher
Positive or negative polarity
Return parameter
Returns the pulse runt search trigger polarity.
Example
:SEARCH:TRIGger:RUNT:POLarity POSitive
Sets the Pulse Runt search trigger polarity to
positive.
:SEARCH:TRIGger:RISEFall:SLOP
Description
Sets or queries the slope of the Rise and Fall search
trigger.
Syntax
:SEARCH:TRIGger:RISEFall:SLOP { RISe | FALL |
EITher | ? }
Related
commands
:SEARCH:TRIGger:TYPe
Parameter
RISe
Rising slope
FALL
Falling slope
EITher
Either rising or falling slope
Return parameter
Returns the rise & fall slope.
Example
:SEARCH:TRIGger:RISEFall :SLOP RISe
Sets the Rise & Fall search trigger slope to rising.