[:SOURce]:SAFEty:RESult:AREPort:MMETerage (RS232
Interface only)
Sets the MEASURE METER auto reports state of test result.
When sets as ON or 1, the test, after completing, returns
messages which are MEASURE
VALUE of all STEPs. If some STEPs among don’t be tested, it
denotes these STEPs don’t have MEASURE VALUE, returning
+9.910000E+37.
When it sets as OFF or 0, it will not auto report the result.
Parameter: 0 | 1 | OFF | ON
Example: SAFE:RES:AREP:MMET ON
Sets the main unit auto report the MEASURE METER result
after the test is completed.
[:SOURce]:SAFEty:RESult:AREPort:MMETerage? (RS232
Interface only)
Returns the MEASURE METER auto reports state of test result.
Return Parameter: 0 | 1
Example: SAFE:RES:AREP:MMET?
> 1
The MEASURE METER auto report of test result state is ON.