REMOTE CONTROL
261
Example: SAFE:STEP4:OSC:CST?
> +1.000000E-09
The Cs value for OSC of step4 is 1nF.
[:SOURce]:SAFEty:STEP<n>:PAuse[:MESSage]
Sets the string of message in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Parameter: <String>
Example: SAFE:STEP5:PA:MESS GWinstek
The message string for PA of step5 is set to GWInstek.
[:SOURce]:SAFEty:STEP<n>:PAuse[:MESSage]?
Returns the string of message in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Return parameter: <String>
Example: SAFE:STEP5:PA:MESS?
> GWInstek
The message string of step5 is “GWInstek”.
[:SOURce]:SAFEty:STEP<n>:PAuse:UTSIgnal
Sets the status of UNDER TEST SIGNAL in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Parameter: 0 | 1 | OFF | ON
Example: SAFE:STEP5:PA:UTSI ON
Sets the status of UNDER TEST SIGNAL of step5 to ON.