REMOTE CONTROL
225
[:SOURce]:SAFEty:STATus?
Returns the execution status of the current device.
Return Parameter: RUNNING | STOPPED
Example: SAFE:STAT?
> RUNNING
The main unit is testing now.
[:SOURce]:SAFEty:SNUMber?
Returns the MANU step number being set in the memory.
Return Parameter: <NR1>(0 ~ 99)
Example: SAFE:SNUM?
> +2
2 MANU steps have been set in the memory.
[:SOURce]:SAFEty:RESult:ALL[:JUDGment]?
Returns the all STEP judgment results.
Return Parameter: <NR1>result
Common judgment result code list
Screen
Judgment Result
Code (Decimal)
PASS
PASS
116
STOP
STOP
113
Message
CAN NOT TEST
114
TEST
TESTING
115
STOP
STOP
112
GR CONT.
GR CONT.
120
GFCI
GFCI
121
POWERGND
POWER GND
122
V OVER
VOLT OVER
123
V LOW
VOLT LOW
124