REMOTE CONTROL
235
> +4.000000E+03
The test voltage value for ACW of step1 is 4000V.
[:SOURce]:SAFEty:STEP<n>:AC:LIMit[:HIGH]
Sets the leakage current high limit for ACW in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Parameter: <NRf>
Example: SAFE:STEP1:AC:LIM 0.01
Sets the leakage current high limit for ACW of step1 to 10mA.
[:SOURce]:SAFEty:STEP<n>:AC:LIMit[:HIGH]?
Returns the leakage current high limit for ACW in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Return parameter: <NR3>
Example: SAFE:STEP1:AC:LIM?
> +1.000000E-02
The leakage current high limit for ACW of step1 is 10mA.
[:SOURce]:SAFEty:STEP<n>:AC:LIMit:LOW
Sets the leakage current low limit for ACW in selected step.
Parameter<n>: <NR1>(1 ~ 99)
Parameter: <NRf>
Example: SAFE:STEP1:AC:LIM:LOW 0.0001
Sets the leakage current low limit for ACW of step1 to 0.1mA.
[:SOURce]:SAFEty:STEP<n>:AC:LIMit:LOW?
Returns the leakage current low limit for ACW in selected step.
Parameter<n>: <NR1>(1 ~ 99)