EasyManuals Logo

GW Instek GPT-9500 Series User Manual

GW Instek GPT-9500 Series
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #260 background imageLoading...
Page #260 background image
GPT-9500 Series User Manual
260
Example: SAFE:STEP4:OSC:CHAN:LOW (@(2))
Sets the output channel for OSC of step4 to channel 2 return.
Example: SAFE:STEP4:OSC:CHAN:LOW (@(0))
Sets the output channel for OSC of step4 off for all return.
[:SOURce]:SAFEty:STEP<n>:OSC:CHANnel:LOW?
Returns the output channel status for OSC of scanning test
return(low).
Parameter<n>: <NR1>(1 ~ 99)
Return parameter: (@(CH))
Example: SAFE:STEP4:OSC:CHAN:LOW?
> (@(2))
The output channel for OSC of step4 is set to channel 2 return.
[:SOURce]:SAFEty:STEP<n>:OSC:CSTandard
Sets the Cs value of the selected STEP range under short/open
detection mode.
Parameter<n>: <NR1>(1 ~ 99)
Parameter: <NR1>(Range:1~3) , <NRf>(Cs)
Example: SAFE:STEP4:OSC:CST 1,0.000000001
It indicates range 1 Cs value of the main unit STEP4 under
short/open detection mode is 1nF.
[:SOURce]:SAFEty:STEP<n>:OSC:CSTandard?
Returns the Cs value of the selected STEP range under
short/open detection mode.
Parameter<n>: <NR1>(1 ~ 99)
Return paramter: <NR3>

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-9500 Series and is the answer not in the manual?

GW Instek GPT-9500 Series Specifications

General IconGeneral
BrandGW Instek
ModelGPT-9500 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals