9.3 Communication Methods
139
99
:CONFigure:WITHstand:CNHI
Sets the contact check upper-limit voltage for withstand-
voltage tests.
157
:CONFigure:WITHstand:CNHI?
Queries the contact check upper-limit voltage for with-
stand-voltage tests.
157
:CONFigure:WITHstand:CNLO
Sets the contact check lower-limit voltage for withstand-
voltage-tests.
158
:CONFigure:WITHstand:CNLO?
Queries the contact check lower-limit voltage for with-
stand-voltage tests.
158
:WITHstand:CLOWer
Enables and disables the lower-limit test value for with-
stand-voltage tests.
158
:WITHstand:CLOWer?
Queries the lower-limit test value enablement for with-
stand voltage tests.
158
:WITHstand:TIMer
Enables and disables the test time for withstand-voltage
tests.
159
:WITHstand:TIMer?
Queries the test time enablement for withstand-voltage
tests.
159
:WITHstand:UTIMer
Sets the ramp-up time ON/OFF for withstand-voltage
tests.
160
:WITHstand:UTIMer?
Queries the ramp-up time ON/OFF for withstand-volt-
age tests.
160
:WITHstand:DTIMer
Sets the ramp-down time ON/OFF for withstand-voltage
tests.
160
:WITHstand:DTIMer?
Queries the ramp-down time ON/OFF for withstand-
voltage tests.
160
:WITHstand:CNHI
Sets the contact check upper-limit voltage ON/OFF for
withstand-voltage tests.
161
:WITHstand:CNHI?
Queries the contact check upper-limit voltage ON/OFF
for withstand-voltage tests.
161
:WITHstand:CNLO
Sets the contact check lower-limit voltage ON/OFF for
withstand-voltage tests.
161
:WITHstand:CNLO?
Queries the contact check lower-limit voltage ON/OFF
for withstand-voltage tests.
161
:MEASure:RESult:WITHstand?
Queries the withstand-voltage test result. 162
:MEASure:WITHstand:VOLTage?
Queries the measured voltage value for withstand-volt-
age tests.
162
:MEASure:WITHstand:CURRent?
Queries the measured current value for withstand-volt-
age tests.
163
:MEASure:WITHstand:TIMer?
Queries the test time elapsed for withstand-voltage
tests.
163
:MEMory:WITHstand:FILE?
Queries the contents of the set-value memory for with-
stand-voltage tests.
164
:MEMory:WITHstand:LOAD
Loads the set-value memory for withstand-voltage tests. 164
:MEMory:WITHstand:SAVE
Saves set values for withstand-voltage tests in memory. 165
:MEMory:WITHstand:CLEar
Clears the set-value memory for withstand-voltage
tests.
165
:CONFigure:INSulation?
Queries the contents of the set-value for insulation-
resistance tests.
165
:CONFigure:INSulation:VOLTage
Sets the test-voltage value for insulation-resistance
tests.
166
:CONFigure:INSulation:VOLTage?
Queries the test-voltage value for insulation-resistance
tests.
166
:CONFigure:INSulation:RUPPer
Sets the upper-limit test value for insulation-resistance
tests.
166
:CONFigure:INSulation:RUPPer?
Queries the upper-limit test value for insulation-resis-
tance tests.
166
Command Explanation
Ref
page