192 Translation of Original Operating Manual 156319-04
0 1000 1500 2000
2800
2500 3000
Motordrehzahl
Delivery volume l/min
10
20
30
40
50
60
70
80
90
50 litres
60 litres
70 litres
80 litres
Coding
C270_135
1. Press the safety switch (1) upwards to switch
it off. Oil supply is switched off. Indicator
lamp goes out.
ADVICE
If you shut off the engine without hav-
ing previously switched off the imple-
ment servo pump or volume divider II
(see page 188) the implement servop-
ump cannot be switched on again im-
mediately for safety reasons.
Before restarting you must first either:
1. set the rotary knob to 0 or
2. turn the safety switch on and off one time.
* Optional equipment