Holder C270 - Fault Cause Remedy

Default Icon
273 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Cause Remedy C250 ... C370
210 Translation of Original Operating Manual 156319-04
Fault Cause Remedy
No power supply for the electronics Check fuses
Electrical connection to servopump
interrupted
Check electrical connection, restore con-
nection
1)
Direction switch defective or poor
contact
Replace direction switch, restore con-
tact
1)
Drive programme switch set to 0 Select desired drive programme
Drive programme switch defective Replace drive programme switch
1)
Hydraulic valve for slow/fast defec-
tive or no pressure available
Check low-pressure valve
1)
Fast-slow cannot be
switched
Electrical connection to hydraulic
valve for fast/slow interrupted, or
bad contact
Restore connection
1)
Diesel engine does not reach a
maximum engine speed
Check accelerator pedal linkage
1)
Check diesel engine
1)
Inch pedal not at maximum speed Adjust inch potentiometer, carry out cali-
bration
1)
Throttle pedal faulty Check throttle pedal, linkage
No maximum speed pos-
sible
Servopump does not swivel out
completely
Check maximum current, proportional
solenoid
1)

Table of Contents