Fault Cause Remedy C250 ... C370
Translation of Original Operating Manual 156319-04 211
Fault Cause Remedy
Inch pedal in wrong position, possi-
ble foreign body in actuator
Adjust correctly, remove foreign body
1)
Does not stop even
with inch pedal fully de-
pressed
Inch potentiometer incorrectly ad-
justed
Adjust inch potentiometer, carry out cali-
bration
1)
Inch pedal defective or no contact Replace inch potentiometer, carry out
calibration
1)
Repair cable connection
1)
Inch pedal not working
Electronics box defective Replace electronics box
1)
Idling speed of engine too high Check engine, check idling speed, check
actuation
1)
Vehicle does not stop in
driving programme 1 or
2 when the gas pedal is
not pressed
Calibration incorrect Carry out calibration
1)
Fuse defective or poor contact Check fuse,
restore connection
Switch defective Check switch, replace if necessary
1)
Hydraulic valve (low pressure
valve) for differential lock defective
or no pressure available
Check hydraulics and hydraulic valve
1)
No power supply Check electrical connections, check ca-
bles and repair
1)
Differential locks do not
shift
Differential lock on wheel motor
too sluggish
Repair
1)