COMMISSIONING
216 Service Manual Part No.: 4417340 Revision 1
954 SmartServo FlexLine
Safety Function Status Code User Action Latching
Default
Burnout
Default
DATA MEMORY FAILURE
A failure of the FII-SIL data memory has
occurred.
Replace the
CAN-SIL board
Enabled High
CODE CHECKSUM FAILURE
The FII-SIL module code memory has
become corrupted.
Replace the
CAN-SIL board
Enabled High
OUTPUT READBACK FAILURE
The contact state or analog output level
cannot be verified.
Replace the
CAN-SIL board
Enabled High
BOARD FAILURE
A failure of the FII-SIL module
electronics has occurred.
Replace the
CAN-SIL board
Enabled High
FUNCTION FAILURE
A failure of the FII-SIL module software
has occurred.
Replace the
CAN-SIL board
Disabled High