3 - 33
PN 074-550-P1C
SQC-310 Operating Manual
Sensors: Allows the operator to choose between various sensor conditions.
Available sensor conditions include:
Sensor Enabled (choose sensor 1 to 4)
Sensor Shutter (choose sensor 1 to 4)
Sensor Fail (choose sensor 1 to 4)
All Crystals Fail
All Crystals Good
Dual Crystal Shutter (choose dual sensor 1 or 2)
Sensor Timeout (choose sensor 1 to 4)
Sources: Allows the operator to choose between various source conditions.
Available source conditions include:
Source Enabled (choose source 1 to 4)
Source Shutter (choose source 1 to 4)
Source Timeout (choose source 1 to 4)
Internal States: Allows the operator to choose an internal state as a condition.
Available states include:
Stopped
Crystal Verify
Initialized Layer
Manual Start Layer
Rotate Crystal
Rotate Pocket
Preconditioning
Soak Hold
Shutter Delay
Deposit
Timed Power Recovery
Crystal Switch
Next Crystal
Feed Ramp
Idle Ramp
Start Next Layer

Table of Contents