8 ADDITIONAL FUNCTIONS DACS-W Operation Manual
8-4
Table 8-1 Installation Engineer Level Functions (1)
Key Display Function
Statistics and
Print Setting
Span Adjustment Print Prints span adjustment records (for equipment with printers)
See "8.4.1 Span Adjustment Print"
Reject Setting Proper Wt. Rej. Dir. Sets the reject direction for proper weight items. [See "8.4.2.1 Proper
Weight Reject Direction"]
Over Wt. Rej. Dir. Sets the reject direction for overweight items.
[See "8.4.2.2 Over Weight Reject Direction"]
Under Wt. Rej. Dir. Sets the reject direction for underweight items.
[See "8.4.2.3 Under Weight Reject Direction"]
Metal Detect Rej. Dir. Sets the reject direction for items detected with metal when a metal
detector is installed.
[See "8.4.2.4 Metal Detect Reject Direction"]
Ext.1 Rej. Direction When a signal is input from External unit 1, the pack is rejected in
the direction set via this item. [See "8.4.2.5 External 1 Reject
Direction"]
Ext.2 Rej. Direction When a signal is input from External unit 2, the pack is rejected in
the direction set via this item. [See "8.4.2.6 External 2 Reject
Direction"]
Zero Error Reject Dir. Sets the direction packs are rejected when a zero error occurs. [See
"8.4.2.7 Zero Error Reject Direction"]
Double Item Rej. Dir. Sets the direction packs are rejected when a double item error occurs.
[See "8.4.2.8 Double Item Reject Direction"]
Proper Weight Signal Sets the signal to be output when a proper pack passes. [See "8.4.2.9
Proper Weight Output Signal"]
Over Weight Signal Sets the signal to be output when an overweight pack passes. [See
"8.4.2.10 Over Weight Output Signal"]
Under Weight Signal Sets the signal to be output when an underweight pack passes. [See
"8.4.2.11 Under Weight Output Signal"]
Metal Detection Signal When a metal detector is installed, sets the signal to be output when
metal is detected in a pack. [See "8.4.2.12 Metal Detection Output
Signal"]
Ext.1 Output Signal When a signal is input from External unit 1, this item sets the signal
to be output for the pack to be rejected in the set direction.
[See "8.4.2.13 External 1 Output Signal"]
Ext.2 Output Signal When a signal is input from External unit 2, this item sets the signal
to be output for the pack to be rejected in the set direction.
[See "8.4.2.14 External 2 Output Signal"]
Zero Error Signal Sets signal to be output each time a zero error occurs. [See "8.4.2.15
Zero Error Output Signal"]
Double Item Signal Sets signal to be output each time a double item error occurs. [See
"8.4.2.16 Double Item Output Signal"]