EasyManuals Logo

Keysight Technologies B2961A Command Reference

Keysight Technologies B2961A
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #299 background imageLoading...
Page #299 background image
Keysight B2961A/B2962A SCPI Command Reference, Edition 6 4- 161
Subsystem Commands
STATus Subsystem
For <CALibration|CURRent|TEMPerature|TEST|VOLTage>, specify CALibration
for the questionable calibration status condition register, CURRent for the
questionable current status condition register, TEMPerature for the questionable
temperature status condition register, TEST for the questionable self-test status
condition register, or VOLTage for the questionable voltage status condition register.
Query response value <newline>
value returns the present setting of the specified event register. It is the sum of the
binary-weighted values for the set bits. Response data type is NR1 (decimal) or
NDN (binary, octal, or hexadecimal) selected by the
:FORMat:SREGister
command.
Example :STAT:QUES:CURR:EVEN?
:STAT:QUES:VOLT:EVEN?
:STAT:QUES:TEMP:EVEN?
:STATus:QUEStionable:<CALibration|CURRent|TEM
Perature|TEST|VOLTage>:NTRansition
Sets the negative transition filter in the questionable calibration, current,
temperature, test, or voltage status register. If you set a bit of the filter, a 1-to-0
transition of its register bit sets the corresponding bit of the event register.
Syntax :STATus:QUEStionable:<CALibration|CURRent|TEMPerature|TEST|VOLTage>:N
TRansition filter
:STATus:QUEStionable:<CALibration|CURRent|TEMPerature|TEST|VOLTage>:N
TRansition?
For <CALibration|CURRent|TEMPerature|TEST|VOLTage>, specify CALibration
for the questionable calibration status condition register, CURRent for the
questionable current status condition register, TEMPerature for the questionable
temperature status condition register, TEST for the questionable self-test status
condition register, or VOLTage for the questionable voltage status condition register.
Parameter filter Negative transition filter. 0 to 65535 (decimal). Default is 0.
Parameter data type is NR1 or NDN.
filter is the sum of the binary-weighted values for the set bits.
Query response filter <newline>

Table of Contents

Other manuals for Keysight Technologies B2961A