Field Option Description
End ID Editable field Available for Filter to show: Range of
p
oint IDs. The last point to be displayed.
Wildcard Editable field Available for Filter to show: Pt IDs match-
ing wildcard. * and ? are supported. * indi-
cates an undefined number of unknown
characters. ? indicates a single unknown
character.
Start date Editable field Available for Filter to show: Time. The date
of the first point to be displayed.
Start time Editable field Available for Filter to show: Time. The time
of the first point to be displayed.
End date Editable field Available for Filter to show: Time. The date
of the last point to be displayed.
End time Editable field Available for Filter to show: Time. The time
of the last point to be displayed.
Control
(Ctrl),
Adjusted
(Adj),
Reference
(Ref),
Measured
(Meas),
Navigated
(Nav),
Estimated
(Est),
None
Show or
Hide
Available for Filter to show: Certain point
classes only. Defined classes are shown or
hidden.
View Available for Filter to show: Certain point
classes only.
Highest
triplet
The coordinate triplets of the highest class
are shown.
All triplets All classes for one coordinate triplet are
shown.
Instrument All, TS, GS,
Office,
Level, Con-
troller, Third
party SW or
Unknown
Available for Filter to show: Pts created by
instrument. Points originating from this
instrument type are shown.
List of
ranges
Editable field Available for Filter to show: Multiple point
ID ranges.
Enter the first and the last point of a range
to be displayed. Single point entry is valid.
•
,: Separa
tes the ranges.
•
-: Separates the first and the last point
of a range
Example: 1-20,25,30-40