Description of fields
Field Option Description
Distance Editable field Click in the field and enter a distance.
Tap ou
tside the field to stop the editing
process.
The distance entered, is shown in the colour
selec
ted in the adjoining Colour field is used.
For a smooth transition to the colour apply-
ing to the distance field below, the colours
are shaded.
Colour Selectable list The selected colour is used to display the
objects at the defined distance.
Click on the field to open the selectable list.
Scroll up and down to see the whole colour
range.
Tap on a colour for selection.
Tap outside the field to stop the selection
process.
60.4 Creating a Reference Surface
60.4.1 From Existing Scans
Select Fr
om existing scans in Define Reference Surface.
Check the box in front of a scan ID to select a scan to use.
Uncheck the b
ox in f
ront of a scan ID to deselect a scan.
Key Description
OK To continue to the next panel.
Fn Settings T
o configure the app. Refer to "60.3 Configuring Inspect sur-
faces".
Fn Delete To delete the highlighted scans.
Fn None or
Fn All
To deactivate or activate all scans for the reference plane
definition.
Next step
OK to ac
cess Define Object to Compare.
60.4.2 From Existing Points
Select From existing points in Define Reference Surface.
Tap on the points forming the reference surface.
Or selec
t a point from the points list on the Points page. Refer to "7.2 Access-
ing Data Management".
Access
Select Scans
Access
Select Points,
3D viewer page
Insp
ect Surfaces 983

Table of Contents