Diagnostic information 2-83
7562
126.xx—LVPS error service check
Step Questions / actions Yes No
1 Turn the printer off, open the system board
shield, and remove the RIP card shield.
Check the cables in connector JLVPS1 and
J17 (E) for proper connection to the system
board.
Are the cables properly connected?
Go to step 2. Reseat the cables.
2
Check the cables for damage.
Are the cables damaged?
Replace the LVPS. See
“Low-voltage power
supply (LVPS) removal”
on page 4-81.
Replace the system board.
See “System board
removal” on page 4-149.