Diagnostic aids 3-19
7562
Sensor Test
Use this test to determine if the input tray sensors are working correctly.
To run the Sensor Test:
1. From the Diagnostics menu, navigate to:
INPUT TRAY TESTS > Sensor Test
2. Select the input source. All installed sources appear.
Not all sensors appear for all trays. The following table indicates which tray sensors are available for each
input source:
3. Manually actuate each sensor. The tray empty sensor can be actuated by hand; however, a sheet of paper
can be used to cover the pass-through sensor. When the sensor is closed, Closed appears. When the
sensor is open, Open appears.
4. Touch Back or press Stop (X) to exit the test.
Input source
Empty
sensor
Low
sensor
PassThru
sensor
Tray Level
sensor
1
Side
Cover
sensor
Standard tray
Optional 550-sheet
drawer
OR
2000-sheet drawer
Multipurpose feeder
1
This sensor registers the following states: Empty, Low, Mid, and Full.