EasyManua.ls Logo

Lexmark X792 - Exiting the Diagnostics Mode; Dual Diode Adjust

Lexmark X792
859 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-10 Service Manual
7562
Go Back
Previous
Next
Exiting the Diagnostics mode
Select EXIT DIAGS to exit the Diagnostics mode and return to the printer home screen.
DUAL DIODE ADJUST
Adjust the dual diode alignment before adjusting the Registration or Alignment settings.
1. From the Diagnostics menu, navigate to:
DUAL DIODE ADJUST > Diode Alignment Page
An alignment page prints.
2. Follow the instructions on the alignment page and use the touch screen to adjust the dual diode alignment
for Black, Cyan, Magenta, and Yellow.
3. Reprint the alignment page and adjust the settings as needed.
Model Name See “Model Name” on page 3-25.
Configuration ID See “Configuration ID” on page 3-25.
Reset Color Cal See “Reset Color Calibration” on page 3-26.
Edge to Edge See “Edge to Edge” on page 3-26.
Cal Ref Adj See “Cal Ref Adj” on page 3-26.
Enable Edge to Edge Copy See “Enable Edge to Edge Copy” on page 3-26.
Par 1 Strobe Adj (if installed) See “Par 1 Strobe Adj” on page 3-26.
EP SETUP
EP Defaults See “EP Defaults” on page 3-26.
Fuser Temp See “Fuser Temp” on page 3-27.
DC Charge Adjust See “DC Charge Adjustment” on page 3-27.
Dev Bias Adj See “Dev Bias Adj” on page 3-27.
Transfer Adjust See “Transfer Adjust” on page 3-27.
Op Point Boost See “Op Point Boost” on page 3-27.
REPORTS
Menu Settings Page
EVENT LOG
Display Log See “Display Log” on page 3-27.
Print Log See “Print Log” on page 3-27.
Clear Log See “Clear Log” on page 3-27.
SCANNER TESTS
Scanner Calibration Reset See “Scanner Calibration Reset” on page 3-28.
ASIC Test See “ASIC Test” on page 3-28.
Feed Test See “Feed Test” on page 3-28.
Sensor Test See “Sensor Test” on page 3-28.
ADF Magnification See “ADF Magnification” on page 3-28.
EXIT DIAGS

Table of Contents