4-42 Service Manual
7562
Installation notes:
1. Attach the memory block and tie the string to its cable.
2. Connect the sensor cable to the sensor, and then attach the sensor to the memory block.
3. From the rear of the printer, pull the string to feed the memory block cable through the frame to the
system board.
Warning: Make sure to pull the cable into the system board cage area as far as possible. Failure to do
may damage the cables.
Cartridge metering cable removal
See “M+K cartridge metering cable” on page 7-67 and “C+Y cartridge metering cable” on page 7-67 for the
part number.
1. Remove the system board shield. See “System board shield removal” on page 4-29.
2. Remove the ITU assembly. See “ITU assembly removal” on page 4-72.
3. Disconnect the cyan & yellow cables (A) or the black & magenta cables (B) from the sensors.
Note: To easily route the new cable to the system board, tie a string (at least twelve inches long) to the end of
each sensor cable you disconnect. When you pull the cables through the printer, be careful to leave one end of
each string inside the printer and the other end on the system board.