Repair information 4-67
7562
High-voltage power supply (HVPS) board removal
See “Front” on page 7-7 for the part number.
1. Remove the ITU block assembly. See “ITU block assembly removal” on page 4-75.
2. Remove the rear cover. See “Rear cover removal” on page 4-23.
3. Remove the two screws (A) to remove the RIP card shield from the system board.
4. Disconnect the HVPS cable (B) from the system board.