Lexmark X792 - XX-Black Cartridge Motor Error Service Check

Lexmark X792
859 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostic information 2-89
7562
Go Back
Previous
Next
141.xx—Black cartridge motor error service check
Step Questions / actions Yes No
1 Turn the printer off, open the system board
shield, and remove the RIP card shield.
Check the cable in the connector JKI1 for
proper connection to the system board.
Is the cable properly connected?
Go to step 2. Reseat the cable.
2
Check the cable for damage.
Is the cable damaged?
Replace the BLDC K ITU
cable. See EP drive
assembly removal” on
page 4-54.
Go to step 3.
3
Measure the resistance across the fuse F10
on the system board.
Is the fuse blown?
Replace the system board.
See “System board
removal” on page 4-149.
Go to step 4.