3-26 Service Manual
7562
To set the configuration ID:
1. From the Diagnostics menu, navigate to:
Printer Setup > Configuration ID
2. Enter the Configuration ID 1.
3. Touch the Configuration ID 2 value to select it, and then enter the new Configuration ID 2.
4.
Touch Submit to save and validate the new IDs.
If either ID is invalid, then the printer discards the changes and returns to the original IDs.
If both IDs are valid, then the printer returns to the Diagnostics menu.
Reset Color Calibration
Note: Use this when the color calibration is not correct.
Reset Color Cal resets the alignment of the color planes to factory default settings.
No buttons can be pressed while the printer is resetting the color calibration. The printer automatically returns to
the Diagnostics menu once the reset is complete.
Edge to Edge
When Edge to Edge is set to On, all margins shift to the physical edges of the page.
Note: PPDS interpreters ignore this setting.
Cal Ref Adj
Warning: This setting should not be changed without specific instructions from the next level of support.
Cal Ref Adj adjusts the printer’s toner density and alignment setting.
Enable Edge to Edge Copy
This setting determines if the printer honors the ADF or flatbed edge erase value when copying. If Enable Edge
to Edge Copy is set to On, then all copies are scanned edge to edge. If this value is set to Off, then the printer
checks the “Scan edge to edge” setting in the Copy Settings menu to determine whether to scan edge to edge or
apply the standard border to the copy.
Par 1 Strobe Adj
Parallel Strobe Adjustment enables you to change the amount of time the strobe is sampled in order to
determine if data is available on the parallel port. Increasing the value increases the amount of time by 50 ns per
increment. Decreasing the value decreases the sample time by 50 ns per increment.
Touch Back to return to the Diagnostics menu.
EP SETUP
EP Defaults
The EP Defaults is used to restore each of the printer settings contained in the EP Setup menu to their factory
default value.
To restore the EP Setup settings to factory defaults, select Restore. To exit the menu without restoring the
settings to the factory defaults, touch Back.