3-68 Service Manual
7562
e. To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat
the steps as needed until you are satisfied with the ADF Front settings.
• Adjust the ADF Back:
a. Place the original test page facedown into the ADF, and select Copy Quick Test.
b. Compare the copy to the original test page, and then navigate to:
Adjust Calibration Values > ADF Back Black
c. Adjust the values, and then touch Submit to save your changes.
d. To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat
the steps as needed.
• Adjust the Flatbed:
a. Remove all pages from the ADF, and then load the original test page onto the flatbed scanner.
b. Select Copy Quick Test.
c. Compare the copy to the original test page, and then navigate to:
Adjust Calibration Values > Flatbed Black
d. Adjust the values, and then touch Submit to save your changes.
To check the changes, reload the original test page, and then repeat the Copy Quick Test. Repeat the steps as
needed.