Table of Contents

Questions and Answers

  • C
    Casey LaneSep 7, 2025
    What to do if LSIS SV-IS7 displays Over Current2?
    • V
      Valerie WashingtonSep 7, 2025
      If your LSIS Inverter shows an Over Current2 error, it could be due to a short-circuited output wiring. Check the output wiring. It might also indicate a fault with the electronic semiconductor (IGBT). In this case, do not operate the inverter and contact the retailer or LSIS Customer Support.
  • R
    romerolisaSep 10, 2025
    What to do if LSIS SV-IS7 displays Under Load?
    • D
      Daniel KellySep 10, 2025
      If your LSIS Inverter displays an Under Load error, it could mean there is a motor-load connection problem, so replace the motor and inverter with lower capacity models. It could also mean that the set value for the underload level (PRT-29 and PRT-30) is less than the system’s minimum load, so increase the set value for the underload level.
  • M
    Mark BradfordSep 12, 2025
    How to troubleshoot a FAN Trip error on an LSIS Inverter?
    • A
      Anthony CarrollSep 12, 2025
      If your LSIS Inverter displays a FAN Trip error, there may be a foreign object in the inverter vent where the fan is located, so remove any obstructions from the air inlet or outlet. The cooling fan might also need to be replaced, so replace the cooling fan.
  • L
    laura80Sep 13, 2025
    What does NTC Open mean on my LSIS Inverter?
    • S
      sandrahaydenSep 13, 2025
      If your LSIS Inverter displays an NTC Open error, the ambient temperature might be too low, so keep the ambient temperature above 10?. It could also mean there is a fault with the internal temperature sensor. In this case, contact the retailer or LSIS Customer Support.
  • N
    Nancy MedinaSep 15, 2025
    What to do if LSIS SV-IS7 Inverter displays IP54 FAN Trip?
    • G
      Gregory JamesSep 15, 2025
      If your LSIS Inverter shows an IP54 FAN Trip error, the fan connector might not be connected, so connect the fan connector. The power connector for the internal fan PCB board might also be disconnected, so connect it. Additionally, the cooling fan might need replacement, so replace the cooling fan.
  • R
    Rebecca SchmidtSep 18, 2025
    What does No Motor Trip mean on my LSIS SV-IS7 Inverter?
    • D
      Dorothy ClarkSep 18, 2025
      If your LSIS Inverter displays a No Motor Trip error, the motor might not be connected to the inverter output, so check the wiring connections. It could also mean that the current level for trip detection is not set properly, so check the values of both BAS-13 (Rated current) and PRT-32 (No Motor Level).

Summary

Safety Information

Safety Symbols and Instructions

Explains safety symbols and provides critical operational and handling instructions.

1 About the Product

1.1 Preparing for Installation and Operation

Guides on product inspection, setup, and initial operations.

2 Technical Specifications

3 Installing the Inverter

4 Connecting the Cables

4.3 Wiring Precautions

Lists essential precautions and guidelines for safe and correct inverter wiring.

4.4 Ground Connection

Details the specifications and importance of proper grounding for inverter safety.

4.14 Post-Installation Checklist

A checklist to ensure the inverter has been safely and correctly installed.

4.15 Test Run

Guides on performing the initial test run and setting basic parameters in Easy Start mode.

5 Using the Keypad

5.6 Setting Parameters

Demonstrates how to set parameters like frequency in Monitor mode and other groups.

5.8 Monitoring Faults

Provides information on monitoring faults during operation and handling multiple faults.

6 Basic Functions

6.1 Setting Frequency References

Explains various methods for setting frequency references, including keypad, analog, and RS-485.

6.8 Setting Acceleration and Deceleration Times

Details setting Acc/Dec times based on maximum frequency, operation frequency, and multi-step configuration.

7 Troubleshooting and Maintenance

7.1 Protection Functions

Lists various protection functions like Over Load, Over Voltage, and E-Thermal.

7.3 Troubleshooting Fault Trips

Provides solutions for common fault trips like Over Load, Under Voltage, and Ground Trip.

9 Peripheral Devices

10 Safety Function STO

10.2 About the Safety Function

Explains the Safety Torque Off (STO) function and its operation.

12 Using a Single Phase Power Source