Loading...
Malfunctions during crane operation
14.7 Hydraulic emergency operation acc. to BGR 159
14 - 64 3 302 709 en Operating manual
GMK5150L
12.01.2018
Removing After the emergency operation, you must disconnect the hoses and the
transformer.
On the superstructure
Remove the hoses (2) from the ports (1).
Close off the hoses and connections with
the caps.
On the carrier
Remove the hoses (2) from the ports (1).
Close off the hoses and connections with
the caps.
Remove the transformer (3).