Malfunctions during crane operation
14.7 Hydraulic emergency operation acc. to BGR 159
14 - 64 3 302 709 en Operating manual
GMK5150L
12.01.2018
Removing After the emergency operation, you must disconnect the hoses and the
transformer.
On the superstructure
• Remove the hoses (2) from the ports (1).
• Close off the hoses and connections with
the caps.
On the carrier
• Remove the hoses (2) from the ports (1).
• Close off the hoses and connections with
the caps.
• Remove the transformer (3).