Malfunctions in driving mode
8.1 Emergency stop switch
Operating manual 3 302 709 en 8 - 1
GMK5150L
12.01.2018
8 Malfunctions in driving mode
8.1 Emergency stop switch
Three emergency stop switches are provided
for emergency use:
• Press an emergency stop switch (1), (2) or
(3). The switch latches.
The engine shuts down.
After activating an emergency stop switch;
à Resetting the emergency stop switch, p. 4 - 19.
H
The battery master switch cannot be used as an emergency stop switch for
the engine. The engine continues to run after the battery master switch has
been switched off.
1 On the carrier
2 On the hand-held control unit
3 In the crane cab