EasyManua.ls Logo

Manitowoc GROVE GMK5150L

Manitowoc GROVE GMK5150L
1040 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Malfunctions during crane operation
14.6 Hydraulic emergency operation with the hand pump
Operating manual 3 302 709 en 14 - 51
GMK5150L
12.01.2018
14.6 Hydraulic emergency operation with the hand pump
H
This section only applies to the standard hydraulic emergency operation.
With the appropriate equipment you can also use the hydraulic emergency
operation according to BGR 159;
à p. 14 - 59.
14.6.1 Operating principle
In hydraulic emergency operation, you can
operate the derricking gear and perform the
Lower main hoist movement, for example, to
raise the main boom in the case of a defective
engine.
The hand pump (1), which is activated by
switching over a valve, is used as the energy
source for the crane's hydraulic system.
The hydraulic circuits are switched via the
valves (2).
The crane movements are performed by
operating the hand pump.
G
Danger from mutual interference of the power units
Check the positions of the valves 1 to 5 for the hydraulic emergency opera-
tion in accordance with BGR (in case available) and, if necessary, switch to
Crane operation; à p. 14 - 67.
This prevents the power units suddenly starting to move.

Table of Contents

Related product manuals