Starting the engine for driving / switching it off
4.3 Air intake inhibitor
4 - 20 3 302 709 en Operating manual
GMK5150L
12.01.2018
4.3 Air intake inhibitor
If the air intake inhibitor is triggered, a flap in the air intake line will close
and the engine will stop running – symbol (1) red – in the start menu display
area;
à p. 8 - 13.
The air intake inhibitor is triggered,
if an emergency stop switch is actuated or
when the maximum permissible engine speed is exceeded. In this case,
the symbol (1) will turn red – in the start menu display area;
à p. 8 - 13.
The symbol stays red until the ignition has been switched off.
The engine can be restarted only after the flap has been opened.
Opening the air
intake inhibitor
The following requirements must be met in order to open the air intake
inhibitor:
The ignition must be switched off.
The emergency stop switch must be reset.
The indicator (2) shows the current state of the
air intake inhibitor (1).
(A) – The indicator (2) is in the
closed position.
Pull as far as possible on the handle (3).
(B) – Insert the pin (3) into the holder (4) –
in the
opened position.