Malfunctions during crane operation
14.7 Hydraulic emergency operation acc. to BGR 159
Operating manual 3 302 709 en 14 - 73
GMK5150L
12.01.2018
14.7.9 Emergency supply of another crane
For emergency
supply
The hoses are assigned according to the various diameters.
On the crane to be supplied
Attach the transformer (3).
Attach the hoses (4); à Operating manual
of the other crane
.
On the GMK5150L
Switch the engine off.
Connect the hoses (2) to the connec-
tions (1).
Switch on the hydraulic emergency
operation;
à p. 14 - 65.
After emergency
supply
On the GMK5150L
Switch off the hydraulic emergency opera-
tion;
à p. 14 - 65.
Remove the hoses (2) from the connec-
tions (1).
On the crane that was supplied
Disconnect the hoses (4).
Remove the transformer (3).
Close all the hoses and connections with
the caps.