Loading...
Malfunctions during crane operation
14.4 Troubleshooting
14 - 26 3 302 709 en Operating manual
GMK5150L
12.01.2018
14.4.17 Malfunctions on the CraneSTAR system
If an error is present, then check the fuses and the electronic connections.
Checking
Loosen the bolts (2) and remove the
cover (1).
Check the associated fuse on the plate (3)
and replace it if necessary:
à Fuses in the
crane cab
, p. 14 - 75.
Loosen the screws (4) and fold down the
plate (3) to the front.
S
Risk of damage if procedure is incorrect
Observe the following notes to avoid malfunctions and damage.
Always switch the ignition off before changing a fuse and before
checking the antenna plugs.
Replace blown fuses only with new fuses of the same amperage.