Malfunctions during crane operation
14.7 Hydraulic emergency operation acc. to BGR 159
14 - 70 3 302 709 en Operating manual
GMK5150L
12.01.2018
For slewing After switching over the valves behind the crane cab, you must also close a
valve.
(A) – Emergency operation position
Close the valve 6 – lever (1) at right angles to
the line.
(B) – Crane operation position
Open the valve 6 – lever (1) parallel to the
pipe.