Driving
5.6 Heating and air-conditioning system
5 - 74 3 302 709 en Operating manual
GMK5150L
12.01.2018
• At the flashing display, set the minutes and confirm the selection.
The time and day of the week have now been set.
Storing the
heating start
Heating is started automatically on schedule only if the time and the day of
the week have been correctly set;
à Setting the date and time, p. 5 - 73.
You can set three different automatic heating starts – up to seven days in
advance.
H
If you call up values in order to change them during the following setting
process, they flash for 5 seconds. The entry must be made within this
period. The value stops flashing after 5 seconds and is saved as the
new value.
• Select and confirm the symbol Timer (1) – display symbol Add timer (2).
• Select and confirm the symbol Add timer (2).
• Select and confirm the desired day of the week, for instance MON for
Monday.
The
Switch-on time display flashes.
• At the flashing display, set the hours and confirm the selection.
• At the flashing display, set the minutes and confirm the selection.
The switch-on time is now set.
Next you must set the switch-off time.
The
Switch-off time display flashes.
• At the flashing display, set the hours and confirm the selection.
• At the flashing display, set the minutes and confirm the selection.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK5150L and is the answer not in the manual?

Manitowoc GROVE GMK5150L Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK5150L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals