Malfunctions in driving mode
8.7 Fuses on the carrier
Operating manual 3 302 709 en 8 - 49
GMK5150L
12.01.2018
8.7 Fuses on the carrier
The fuses are divided into groups and are at various points on the carrier:
In the driver's cab,
In the battery box.
Information on
changing fuses
The positions of the fuses, their designations and which functions are
protected by the respective fuses are shown in the following sections.
Switch off the ignition whenever a fuse has to be replaced.
S
Risk of damage if the ignition is switched on
Switch off the ignition whenever a fuse has to be replaced. This prevents
the new fuse being blown immediately by the increased starting current
after being installed.
S
Risk of damage by overloading
Replace blown fuses only with new fuses of the same amperage. This pre-
vents parts being overloaded and damaged or the fuse being immediately
blown again.
Notify
Manitowoc Crane Care if a fuse with the same amperage blows again
when the ignition is switched on.
S
Risk of fire
Never repair a blown fuse with other electrically conductive materials.