2 - 16
2.5 IP Filter Setting
2.5 IP Filter Setting
2.5.1 IP filter setting
IP addresses from which access to the GOT is allowed or blocked can be set.
For the details of the IP filter setting, refer to the following.
GT Designer3 (GOT2000) Help
*1 Leave the boxes blank if you do not set any IP addresses.
Item Description Setting range
IP filter usage You can set whether to use or not the IP filter function.
Yes/No
<Default: No>
Access from the following address
You can set whether to allow or block access from the IP addresses that
set in the filtering list.
If [Transmit] is selected
Access from the IP addresses that are set for [Target IP address] is
blocked.
Access from the IP addresses that are set for [Exception IP address] is
disallowed.
If [Block] is selected
Access from the IP addresses that are set for [Target IP address] is
blocked.
Access from the IP addresses that are set for [Exception IP address] is
allowed.
Transmit/Block
<Default: Transmit>
Range
You can set whether to register IP addresses by specifying a range.
To specify a range, set the start IP address and the end IP address for
[Target IP address].
Range specified (Selected)/Range
not specified (Not selected)
<Default: Range not specified>
Target IP address
You can set IP addresses or IP address ranges to be filtered.
Up to 32 ranges can be set.
0.0.0.0 to 255.255.255.255
*1
<Default: Blank>
Exception IP address
This item can be set only when [Range] is selected.
For an IP address range specified in [Target IP address], set IP
addresses excluded from being filtered.
Up to 32 addresses can be set for one range specified in [Target IP
address].
0.0.0.0 to 255.255.255.255
*1
<Default: Blank>

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive

Related product manuals