208
6 BASIC INSTRUCTIONS
6.2 Arithmetic Operation Instructions
Operation error
Error code
(SD0/SD8067)
Description
2820 The range of (n) point(s) of data starting from the device specified by (s1), (s2), or (d) exceed the corresponding device range.
2821 The device range for (n) point(s) beginning from (s1) overlaps with that of (n) point(s) starting from (d).
(Does not apply when same device has been specified for (s1) and (d).)
The device range for (n) point(s) beginning from (s2) overlaps with that of (n) point(s) starting from (d).
(Does not apply when same device has been specified for (s2) and (d).)