15 TYPE CONVERSION FUNCTIONS
15.51 Converting INT to Bit Array
757
15
15.51 Converting INT to Bit Array
INT_TO_BITARR(_E)
These functions output low-order (n) bits of INT type data to a bit array.
Setting data
Descriptions, types, and data types
Processing details
Operation processing
These functions output low-order (n) bits of ANY 16 type data specified to (s).
Output bits beyond the specified number of bits are not changed.
Operation result
1. Function without EN/ENO
The operation processing is executed. The operation output value is output from (d).
2. Function with EN/ENO
The following table lists the execution conditions and operation results.
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
There is no operation error.
Ladder diagram Structured text
[Without EN/ENO] [With EN/ENO] [Without EN/ENO]
d:=INT_TO_BITARR(s,n);
[With EN/ENO]
d:=INT_TO_BITARR_E(EN,ENO,s,n);
Argument Description Type Data type
EN Execution condition (TRUE: Execution, FALSE: Stop) Input variable BOOL
s Input Input variable ANY16
n Only a constant 4, 8, 12 or 16 can be specified. Input variable INT
ENO Output status (TRUE: Normal, FALSE: Abnormal) Output variable BOOL
d Output (Variables are available for element specification.) Output variable BOOL array element
Execution condition Operation result
EN ENO (d)
TRUE (Executes operation) TRUE Operation output value
FALSE (Stops operation) FALSE
*1
Indefinite value
s d
n
EN ENO
sd
n