760
15 TYPE CONVERSION FUNCTIONS
15.54 Reading the Specified Bit of Word Label
15.54 Reading the Specified Bit of Word Label
GET_BIT_OF_INT(_E)
These functions reads the specified bit of the word label
Setting data
Descriptions, types, and data types
Processing details
Operation processing
These functions output (n)th bit of (s).
Operation result
1. Function without EN/ENO
The operation processing is executed. The operation output value is output from (d).
2. Function with EN/ENO
The following table lists the execution conditions and operation results.
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
There is no operation error.
Ladder diagram Structured text
[Without EN/ENO] [With EN/ENO] [Without EN/ENO]
d:=GET_BIT_OF_INT(s,n);
[With EN/ENO]
d:=GET_BIT_OF_INT_E(EN,ENO,s,n);
Argument Description Type Data type
EN Execution condition (TRUE: Execution, FALSE: Stop) Input variable BOOL
s Input Input variable ANY16
n Only a constant 0 to 15 can be specified. Input variable INT
ENO Output status (TRUE: Normal, FALSE: Abnormal) Output variable BOOL
d Output Output variable BOOL
Execution condition Operation result
EN ENO (d)
TRUE (Executes operation) TRUE Operation output value
FALSE (Stops operation) FALSE
*1
Indefinite value
s d
n
EN ENO
sd
n