Operation error
Error code
(SD0/SD8067)
Description
2820 In the corresponding device range after the device specified by (s1), "00H" does not exist.
In the corresponding device range after the device specified by (s2), "00H" does not exist.
2821 The numbers of the character string-storing devices specified by (s1), (s2), and (d) overlap.
3405 The character string specified by (s1) has more than 16383 characters.
The character string specified by (s2) has more than 16383 characters.
3406 The character string specified by (d) has more than 16383 characters.
The whole concatenated character string cannot be stored in the devices from the device specified by (d) to the last device in the
corresponding device range.