7.7 Real Number Instruction
String data in the exponent format is handled as positive value during conversion when the sign of the exponent part is set
to 2BH (+) or when the sign is omitted. When 2DH (-) is specified as the sign, a character string is converted into a negative
value.
When 20H (space) or 30H (0) exists between numbers except the first 0 in a character string specified by (s), 20H or 30H is
ignored during conversion.
When 30H (0) exists between a number and "E" in a character string in the exponent format, 30H is ignored during
conversion.
Operation error
Error code
(SD0/SD8067)
Description
2820 00H does not exist in the corresponding device range starting from (s)
3401 Characters other than 30 (0) to 39 (9) exist in a character string specified by (s)
2EH (.) exists in two or more positions in a character string specified by (s)
Any character other than 45H (E), 2BH (+), or 2DH (-) exists in the exponent part specified by (s), or two or more exponent parts exist
3405 The number of characters after (s) is 0 or more than 24
(d)(d)+1
2EH (.)
34H (4)
33H (3)
2DH (-)
30H (0)
2BH (+)
33H (3)
35H (5)
45H (E)
30H (0)
-
401-. +5E
(s)
(s)+1
(s)+2
(s)+3
(s)+4
(s)+5
(s)+6
b15 b0
b7b8
00H
31H (1)
33
1 . 0 4 5 3 E + 0 3
Single-precision real number
20H (space)
Ignored