9 HIGH-SPEED COUNTER INSTRUCTION
9.1 High-speed Processing Instruction
635
9
Precautions
The value specified in (s2) should only be the channel of high-speed counter number (1 to 8) set by the parameter. If a
channel which is not set by the parameter or a value other than K1 to K8 is specified, an operation error occurs.
For other precautions, refer to User's manual [Application].
Operation error
Error code
(SD0/SD8067)
Description
3780 The DHSCS, DHSCR, and DHSZ instructions are used exceeding the maximum limit of the number of these instructions.
3405 A channel number outside the range or the device (I) number is specified.
3600 A channel number for which the channel setting is not set is specified in the operand for channel number specification of the high-speed
counter.