Training Guide Course No. 196514
Level 2 Maintenance, X-1000 Series Dispensing Systems 2-43 P/N 196515 (Revision A)
Diagram Sheet 2-5-4
Dispensing Head Performs a Height Sense
FmNT Command
PMAC CardPIO96 Card
Main Interface PWA
Dispense Head Controller
X-Y Servo Interface PWA
Main Interface PWA
XY Servo Interface PWA
Z Servo Interface PWA
Dispense Head Controller
XY Servo Interface PWA
Main Interface PWA
Main Interface PWA
XY Servo Interface PWA
Z Servo Interface PWA
Z-Axis Servo Motor Lowers
Dispensing Head
Height Sensor Probe
Contacts Workpiece
Height Sensor Armed
Position Information to
FmNT
PMAC Card Receives
Position Capture
Information and Issues
Motor Stop Command
Z-axis Servo Motor Stops
Lowering
Height Sensor Input Signal
Sent