Training Guide Course No. 196514
Level 2 Maintenance, X-1000 Series Dispensing Systems 2-162 P/N 196515 (Revision A)
Information Sheet 2-18-2
PMAC Plot (Continued)
C. Plotting Data
1. Open the PMAC Plot Program.
Press [Ctrl]-ESC
Select Programs, Pmac Plot, PmacPlot.
2. Click on the Quick Plot tab.
3. Click on Motors to Gather.
Select motors (commanded and actual) to be analyzed.
1 = x-motor, 2 = y-motor, 3 = z-motor.
- The fewer motors selected, the greater the sampling of data.
Set gather period long enough to gather motions being analyzed.
4. Select choices of axis to be plotted.
Select first choice and click on Add to Left or Add to Right.
Repeat with second choice.
5. Click on Define Gather Buffer.
This must be repeated each time prior to running a dispensing program.
It clears the gather buffer.
6. Press [Alt]-Tab to return to FmNT.
7. Run the program.
8. Press [Alt]-Tab to return to PMAC Plot.
9. Click on Upload Data.
10. Click on Plot Data.
11. Plot
Maximize Window
Click far right button, Change Pmacplot Option (See Diagram Sheet 4-
15-2).
Select Scale
Select Left or Right Vertical Axis that has the following error set value:
- Minimum: -20
- Maximum: 20
- Fixed: 5
12. If time needs to be zoomed in, select Scale, Horizontal Axis and set
values.
13. Click OK.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson Asymtek X-1000 Series and is the answer not in the manual?

Nordson Asymtek X-1000 Series Specifications

General IconGeneral
BrandNordson
ModelAsymtek X-1000 Series
CategoryDispenser
LanguageEnglish

Related product manuals