Training Guide Course No. 196514
Level 2 Maintenance, X-1000 Series Dispensing Systems 2-24 P/N 196515 (Revision A)
Diagram Sheet 2-3-1
Power Distribution
Main Power Inlet
Main Circuit Breaker
Power Manager
Computer 250 Watt
Power Supply
Main Interface
PWA
Conveyor
Controller
y
Servo Amplifiers (42-85 VDC)
y
Linear Encoders (5 VDC)
y
Pneumatic Solenoids (24 VDC)
y
Fans (24 VDC)
y
Beacon (24 VDC)
y
Fluorescent Light (12 VDC)
y
Z-Servo Interface (5,24, VDC)
y
Needle Sensor (24 VDC)
y
Spare DC Out (5, 24 VDC)
y
Hour Meter (12 VDC)
y
Scale Power (12 VDC)
y
Monitor (5, 12 VDC)
y
Main CPU Board (+5,-5,-12 VDC)
y
PMAC Card (+12,-12 VDC)
y
ITI Card (5,12 VDC)
y
PIO-96 Card (5 VDC)
y
Other Cards (5,12 VDC)
y
Conveyor Motor
y
Conveyor Sensor
y
Heater Blocks/Needle Heat
208/240 VAC
Emergency Machine Off
(EMO)
Servo Power Transformer
Start Button
240 VAC
24 VDC
208/240 VAC
220 VAC 208/240 VAC
+5,-5,+12, -12
VDC
240 VAC
+5,-5,+12, -12 VDC
XY Servo Interface
+5,-5,+12,-12,24 VDC
+5,-5,+12, -12, 24 VDC
Dispense Head Controller
(5, 24 VDC)
Dispense Valve
(24 VDC)
42-85 VDC
24 VDC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson Asymtek X-1000 Series and is the answer not in the manual?

Nordson Asymtek X-1000 Series Specifications

General IconGeneral
BrandNordson
ModelAsymtek X-1000 Series
CategoryDispenser
LanguageEnglish

Related product manuals