EasyManuals Logo

R&S SMB100A User Manual

R&S SMB100A
528 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #324 background imageLoading...
Page #324 background image
Remote Control Commands
R&S
®
SMB100A
309Operating Manual 1407.0806.32 ─ 21
Return values:
<DirectoryCount> integer
Number of parent and subdirectories.
Example: See "Working with Files and Directories" on page 304.
Usage: Query only
:MMEMory:DELete <Filename>
Removes a file from the specified directory.
Setting parameters:
<Filename> string
String parameter to specify the name and directory of the file to
be removed.
Example: See "Working with Files and Directories" on page 304.
Usage: Event
SCPI confirmed
Manual operation: See "Cut" on page 131
:MEMory:HFRee?
Returns the used and available memory in Kb.
Return values:
<TotalPhysMemKb> integer
Total physical memory.
<ApplicMemKb> integer
Application memory.
<HeapUsedKb> integer
Used heap memory.
<HeapAvailableKb> integer
Available heap memory.
Usage: Query only
:MMEMory:LOAD:STATe <SavRclStateNumb>, <file_name>
Loads the specified file stored under the specified name in an internal memory.
After the file has been loaded, the instrument setting must be activated using an *RCL
command.
Setting parameters:
<SavRclStateNumb> Determines to the specific <number> to be used with the *RCL
command, e.g. *RCL 4.