Remote Control Commands
R&S
®
SMB100A
410Operating Manual 1407.0806.32 ─ 21
Manual operation: See "ARI Identification - Stereo Modulation" on page 216
[:SOURce]:STEReo:ARI:TYPE:STATe <State>
Activates/deactivates the Stereo ARI Identifier.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
STER:ARI:TYPE:STAT ON
Options: R&S SMB-B5
[:SOURce]:STEReo:ARI[:DEViation] <Deviation>
Sets the frequency deviation of the ARI subcarrier signal.
Parameters:
<Deviation> integer
Range: 0 to 10000
*RST: 3500
Example:
STER:ARI:DEV 3.5kHz
sets the frequency deviation of the 57 kHz subcarrier to 3.5kHz.
Options: R&S SMB-B5
Manual operation: See "ARI Deviation - Stereo Modulation " on page 216
[:SOURce]:STEReo:AUDio:MODE <Mode>
Selects the generated identifiers of the AUDio signal.