EasyManua.ls Logo

Ricoh MT-P2 - Page 312

Ricoh MT-P2
537 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Error occurred when ROM update
program started
Controller program defective. If the second attempt fails,
replace the controller board.
24 SD card access error
Make sure the SD card is installed correctly, or use a dif-
ferent SD card.
30
No HDD available for stamp data
download
HDD connection not correct or replace hard disks.
31
Data incorrect for continuous down-
load
Install the SD card with the remaining data necessary for
the download, then re-start the procedure.
32
Data incorrect after download inter-
rupted
Do the recovery procedure for the module, then repeat the
installation procedure.
33 Incorrect SD card version
The ROM data on the SD card is not correct, or data is
damaged.
34
Module mismatch - Correct module
is not on the SD card
The data on the SD is not correct. Get the correct data (Ja-
pan, Overseas, OEM, etc.) then install again.
35
Module mismatch – Module on SD
card is not for this machine
SD update data is not correct. The data on the SD card is
for a different machine. Get the correct data then install
again.
36
Cannot write module – Cause other
than E34, E35
SD update data is not correct. The data on the SD card is
for a different machine. Get the correct data then install
again.
40 Engine module download failed
Replace the data for the module on the SD card and try
again, or replace the BCU board.
42
Operation panel module download
failed
Replace the data for the module on the SD card and try
again, or replace the LCDC.
43
Stamp data module download
failed
Replace the data for the module on the SD card and try
again, or replace the hard disk.
44 Controller module download failed
Replace the data for the module on the SD card and tray
again, or replace the controller board.
50 Electronic confirmation check failed
SD update data is not correct. The data on the SD card is
for a different machine. Get the correct data then install
again.
Service Program Mode
311
5

Table of Contents

Related product manuals