001 Center Temperature
Shows the temperature of the hot roller detected by the thermistor
at the center of the hot roller.
002 End Temperature
Shows the temperature of the hot roller detected by the thermis-
tors at the ends of the hot roller.
1107 Start Fusing Temperature Adjustment
This SP allows you to set when to start the fusing temperature adjustment for the center and
end heating lamps.
001 Center Lamp Temperature
[180~205/205/1 deg C]
002 End Lamp Temperature
003 Center Lamp Actual Time
[0~120/60/1 sec.]
004 End Lamp Actual Time
005 Center Lamp Temp (Small Size Paper) [190~205/205/1 deg C]
006 End Lamp Actual Time (Small Size Paper) [0~120/60/1 sec.]
007 Center Lamp Temp (Thick Paper) [190~205/205/1 deg C]
008 End Lamp Actual Time (Thick Paper) [0~120/60/1 sec.]
1112 [Process Control] Hot Roller Temperature for Process Control
Sets the temperature of the hot roller for auto process control to start.
[70°~150°/1°C] DFU
1159 [Fusing Jam SC Set]
This SP determines what the machine does if paper jams occur in the fusing unit for three
consecutive sheets of paper.
0: (default): A jam alert is shown on the screen. The customer can remove the jam and the
machine works normally after that.
1: SC559 occurs. The technician must remove the jam.
1901 [CPM Down Setting] CPM Down for Special Paper
Selects the speed (copies per minute) for copying on thick paper or tab sheets. A slower
speed makes fusing better. This setting has no effect on fusing temperature.
Service Program Mode Tables
317